| VERO_N_SEGMENT6_CON |
36.13354, -96.21831 |
2026-09-01 |
Conduit_Length |
Unassigned |
6
|
Conduits are too long, must be trimmed down to length. Drain water from vault. Backfill dirt around vault to bring to grade. Ensure all tracer wire is visible |
| VERO_N_SEGMENT3_CON |
36.11645, -96.68635 |
2026-09-01 |
Markerpost |
Unassigned |
6
|
HH label not legible, jumper wire needs to connect between tracer and ground. Restoration needed around vault |
| VERO_N_SEGMENT3_CON |
36.11652, -96.67843 |
2026-09-01 |
Markerpost |
Unassigned |
6
|
marker post wiring needs jumper between both tracer wire and ground post. |
| VERO_N_SEGMENT4_CON |
36.11913, -96.60959 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
softscape restoration needed around vault to bring to grade. jumper wire not connected to ground wire lug. |
| VERO_N_SEGMENT5_CON |
36.12952, -96.30071 |
2026-09-01 |
Structure_Other |
Unassigned |
6
|
Unable to identify all conduit, tracer, and ground rod inside vault. Backfill dirt around vault to bring to grade. |
| VERO_N_SEGMENT6_CON |
36.13351, -96.22677 |
2026-09-01 |
Conduit_Length |
Unassigned |
6
|
Conduits cannot be crossing, pull back to each side of vault. Conduits too long, trim to proper lengths. Ground rod installed incorrectly. |
| VERO_N_SEGMENT6_CON |
36.13230, -96.25208 |
2026-09-01 |
Conduit_Length |
Unassigned |
6
|
Conduit ends too close together, separate conduit for more spacing. Ground rod needs to be driven further into the ground. |
| VERO_N_SEGMENT6_CON |
36.13135, -96.26069 |
2026-09-01 |
Markerpost |
Unassigned |
6
|
tracer wire should not be fully stripped to the copper inside marker post |
| VERO_S_SEGMENT3_CON |
36.08127, -97.05154 |
2026-09-01 |
Conduit_Sealed |
Unassigned |
6
|
Conduit not sealed around fiber. Tape falling off other conduits. |
| VERO_N_SEGMENT4_CON |
36.11909, -96.61801 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
backfill around vault to bring to grade. jumper wire not connected to ground wire lug. |
| VERO_N_SEGMENT7_CON |
36.12045, -96.11723 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
Restoration photos must be taken further back showing full length of softscape, not just a top-down view. Ground wire must be connected to copper lug on marker post. |
| VERO_N_SEGMENT6_CON |
36.13806, -96.19339 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
post-restoration photos must be taken from further back to show full length of softscape around vault. Marker post cap needs vero sticker, not black banding. All tracer wire must be visible inside vault |
| VERO_N_SEGMENT4_CON |
36.11739, -96.51329 |
2026-09-01 |
Markerpost |
Unassigned |
6
|
Marker post wiring photo cut off, need a full picture of the wiring. |
| VERO_N_SEGMENT6_CON |
36.13398, -96.20987 |
2026-09-01 |
Structure_Other |
Unassigned |
6
|
Cannot see inside vault clearly enough, need water drained and new interior photo taken. |
| VERO_N_SEGMENT6_CON |
36.12175, -96.12504 |
2026-09-01 |
Conduit_Sealed |
Unassigned |
6
|
No micro duct caps were available to be put on. |
| VERO_S_SEGMENT3_CON |
36.06745, -97.05156 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
Restoration needed around vault |
| VERO_N_SEGMENT5_CON |
36.12905, -96.32032 |
2026-09-01 |
Structure_Grounding |
Unassigned |
6
|
Ground rod installed incorrectly, needs to be driven further into the ground. All tracer wire must be visible inside vault. Marker post needs vero sticker, not black banding. |
| VERO_N_SEGMENT5_CON |
36.12844, -96.36249 |
2026-09-01 |
Structure_Other |
Unassigned |
6
|
Vero sticker is not present inside vault picture |
| VERO_N_SEGMENT4_CON |
36.11908, -96.60078 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
softscape restoration needed around vault to bring to grade. Jumper wire not connected to ground wire lug. |
| VERO_N_SEGMENT5_CON |
36.12710, -96.33886 |
2026-09-01 |
Structure_Grounding |
Unassigned |
6
|
pull duct back to either sdie of the vault, trim conduit to length afterwards.Ground rod must be driven further into the ground. |
| VERO_S_SEGMENT3_CON |
35.99905, -97.05105 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
massive sinking around vault, vault may need to be raised. Fill in sinking softscape around vault to bring to grade. |
| VERO_N_SEGMENT3_CON |
36.11661, -96.66942 |
2026-09-01 |
Markerpost |
Unassigned |
6
|
tracer and ground wire must have jumper installed connecting all three wires. |
| VERO_N_SEGMENT3_CON |
36.11642, -96.66076 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
softscape restoration around vault needed |
| VERO_S_SEGMENT3_CON |
36.09505, -97.05161 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
Restoration needed around vault. Conduit needs sealant around fiber cables. Remove trash from inside vault |
| VERO_N_SEGMENT4_CON |
36.11639, -96.64279 |
2026-09-01 |
Markerpost |
Unassigned |
6
|
Interior vault photo and marker post photo not from this vault. jumper wire must connect between tracer and ground wire lugs. Ground rod missing. |
| VERO_N_SEGMENT4_CON |
36.12020, -96.51937 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
softscape restoration around vault to bring to grade. Interior photos are too blurry, retake photos. |
| VERO_N_SEGMENT3_CON |
36.11641, -96.65213 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
softscape restoration around vault needed. Marker post jumper wire must be connected to ground and tracer |
| VERO_N_SEGMENT5_CON |
36.12656, -96.34556 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
Conduit cannot be crossed, pull conduit back to both sides of the vault and trim to length. softscape restoration needed in front of vault |
| VERO_N_SEGMENT3_CON |
36.11622, -96.69420 |
2026-09-01 |
Markerpost |
Unassigned |
6
|
Jumper wire needs to be connected between tracers and ground lugs. |
| VERO_S_SEGMENT3_CON |
36.08812, -97.05141 |
2026-09-01 |
Conduit_Sealed |
Unassigned |
6
|
conduit not sealed between fiber |
| VERO_S_SEGMENT3_CON |
36.10186, -97.05153 |
2026-09-01 |
Markerpost |
Unassigned |
6
|
Missing both tracer wires inside marker post. Conduit not sealed, cannot see ground wire. remove trash from vault |
| VERO_N_SEGMENT6_CON |
36.12542, -96.13674 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
Cannot identify vault in exterior photos. Remove dirt from vault lid and take new photos of exterior. Conduits cannot be crossed, pull back conduit to each side of vault. |
| VERO_S_SEGMENT3_CON |
36.03294, -97.05143 |
2026-09-01 |
Conduit_Sealed |
Unassigned |
6
|
Softscape restoration needed around vault by marker post. Conduit not sealed around fiber. |
| VERO_S_SEGMENT3_CON |
36.02624, -97.05143 |
2026-09-01 |
Trash_Scraps |
Unassigned |
6
|
Cannot have trash piles in deliverable photos. Remove trash piles and take new N,E,S,W photos. |
| VERO_N_SEGMENT4_CON |
36.11916, -96.55882 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
softscape restoration needed around vault to bring to grade. |
| VERO_S_SEGMENT3_CON |
36.06029, -97.05144 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
Softscape restortation needed around vault |
| VERO_S_SEGMENT3_CON |
36.07431, -97.05155 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
softscape restoration needed around vault to bring to grade. |
| VERO_S_SEGMENT3_CON |
36.01247, -97.05115 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
backfill around vault to fill in voids. |
| VERO_N_SEGMENT6_CON |
36.13349, -96.23620 |
2026-09-01 |
Conduit_Length |
Unassigned |
6
|
Conduits cannot be crossing, pull conduit back to each side of vault. Trim conduit to length. Ground rod not visible in interior photo. |
| VERO_N_SEGMENT4_CON |
36.12123, -96.52508 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
softscape restoration around vault to bring to grade. Trim conduit down to length. |
| VERO_N_SEGMENT4_CON |
36.12019, -96.54194 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
Marker post photo does not appear to belong to this vault.Softscape restoration around vault to bring to grade. Jumper wire needs to connect to tracer and ground lugs. |
| VERO_N_SEGMENT4_CON |
36.11909, -96.58412 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
Softscape restoration needed around vault to bring to grade. Conduit and tracer wire in vault obscured by dirt/mud |
| VERO_N_SEGMENT4_CON |
36.11910, -96.59267 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
softscape restoration around vault needed to bring to grade. Jumper wire not connected to ground wire lug. |
| VERO_S_SEGMENT3_CON |
35.99232, -97.05102 |
2026-09-01 |
Conduit_Sealed |
Unassigned |
6
|
missing sealant between conduit and fiber cable. |
| VERO_S_SEGMENT3_CON |
36.03959, -97.05144 |
2026-09-01 |
Conduit_Sealed |
Unassigned |
6
|
Conduit not sealed around fiber cable |
| VERO_S_SEGMENT3_CON |
36.05341, -97.05139 |
2026-09-01 |
Conduit_Sealed |
Unassigned |
6
|
Multiple conduit not sealed |
| VERO_N_SEGMENT6_CON |
36.12997, -96.15272 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
Top of vault obscured by mud. Clean off vault lid and re-take restoration photos. Pull back conduit to each side of vault. |
| VERO_S_SEGMENT3_CON |
36.00566, -97.05113 |
2026-09-01 |
Conduit_Sealed |
Unassigned |
6
|
Conduit not sealed around fiber cable. Ground rod not visible. |
| VERO_N_SEGMENT5_CON |
36.13026, -96.28400 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
Backfill material around vault to bring to grade. Remove mule tape from vault lid. |
| VERO_N_SEGMENT5_CON |
36.13054, -96.27560 |
2026-09-01 |
Restoration_Other |
Unassigned |
6
|
backfill material around vault to bring to grade. Missing interior vault photo. |
| VERO_S_SEGMENT3_CON |
36.04656, -97.05133 |
2026-09-01 |
Trash_Scraps |
Unassigned |
6
|
remove trash from inside vault |
| VERO_N_SEGMENT5_CON |
36.12978, -96.29227 |
2026-09-01 |
Conduit_Length |
Unassigned |
6
|
Pull back conduit towards both ends of vault, trim conduit if needed once pulled back. Expose all tracer wire and the ground rod. |
| VERO_N_SEGMENT5_CON |
36.12913, -96.30916 |
2026-09-01 |
Structure_Other |
Unassigned |
6
|
Missing interior vault photo. Backfill around vault to bring to grade. |
| VERO_N_SEGMENT6_CON |
36.12192, -96.12497 |
2026-09-01 |
Structure_Grounding |
Unassigned |
6
|
Ground rod needs to be placed in a corner of the vault and lower into the ground. |
| VERO_N_SEGMENT6_CON |
36.12157, -96.12377 |
2026-08-28 |
Conduit_Sealed |
Unassigned |
10
|
Crews are out of the caps. They are not able to get any from the warehouse because we are out. |
| VERO_N_SEGMENT5_CON |
36.11718, -96.62614 |
2026-08-27 |
Markerpost |
Unassigned |
11
|
|
| VERO_N_SEGMENT5_CON |
36.11937, -96.55024 |
2026-08-27 |
Other |
Unassigned |
11
|
Mud in vault |
| VERO_N_SEGMENT2_CON |
36.11639, -96.89870 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Missing marker / grounding post |
| VERO_N_SEGMENT2_CON |
36.11618, -96.89004 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Missing marker post cap. |
| VERO_N_SEGMENT2_CON |
36.11601, -96.86683 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Terminals need to be cut to fit marker post |
| VERO_N_SEGMENT4_CON |
36.11907, -96.57615 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Marker Post - Connect both tracer and ground with a jumper. Missing HH label and black band. |
| VERO_N_SEGMENT3_CON |
36.11529, -96.80691 |
2026-08-26 |
Pole_Grounding |
Unassigned |
12
|
Jumper wire needs to be connected to ground and tracer inside marker post. All tracer wire must be visible inside of the vault. Remove mule tape from vault lid. |
| VERO_N_SEGMENT4_CON |
36.11716, -96.62613 |
2026-08-26 |
Structure_Other |
Unassigned |
12
|
Missing all photos. |
| VERO_N_SEGMENT3_CON |
36.11253, -96.79168 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
(might want to wait until fiber has been fully installed to clear these) HH label not legible in photo, Clean up rocks surrounding vault. Conduit needs capped (possibly take after fiber has been installed). Remove mule tape from vault lid. |
| VERO_N_SEGMENT2_CON |
36.11577, -96.84968 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Post - Connect all tracer and ground with jumper, clear photo of HH label, all tracer wire must be visible inside vault |
| VERO_N_SEGMENT5_CON |
36.13063, -96.37378 |
2026-08-26 |
Restoration_Other |
Unassigned |
12
|
Cond. it cannot cross. Pull back conduit to both sides of the vault, trim extra length afterwards. Softscape restoration needed around vault to bring vault to grade. Inside vault photo needs Vero sticker. |
| VERO_S_SEGMENT3_CON |
35.98569, -96.85753 |
2026-08-26 |
Structure_Other |
Unassigned |
12
|
Connect tracer wire and ground with jumper wire inside marker post. Backfill dirt around vault to bring vault to grade. |
| VERO_S_SEGMENT3_CON |
35.98569, -96.85753 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer wire and ground with jumper wire inside marker post. Backfill dirt around vault to bring vault to grade. |
| VERO_S_SEGMENT3_CON |
35.98496, -96.76892 |
2026-08-26 |
Pole_Grounding |
Unassigned |
12
|
No photo of inside marker post, make sure tracer and ground has a jumper together. Conduit not capped. Unable to see ground rod. |
| VERO_S_SEGMENT3_CON |
35.98498, -96.71304 |
2026-08-26 |
Restoration_Other |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape. Missing photo of interior vault and vero sticker. |
| VERO_S_SEGMENT3_CON |
35.98498, -96.71304 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape. Missing photo of interior vault and vero sticker. |
| VERO_S_SEGMENT3_CON |
35.98530, -97.04887 |
2026-08-26 |
Pole_Grounding |
Unassigned |
12
|
Marker post needs jumper between ground and tracers. Missing seal on conduit |
| VERO_S_SEGMENT3_CON |
35.98557, -96.83241 |
2026-08-26 |
Structure_Other |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Unbury tracer wire inside vault. Trim three-way conduit. Conduit obscured by fiber (can't see sealant) |
| VERO_S_SEGMENT3_CON |
35.98557, -96.83241 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Unbury tracer wire inside vault. Trim three-way conduit. Conduit obscured by fiber (can't see sealant) |
| VERO_N_SEGMENT2_CON |
36.11596, -96.99959 |
2026-08-27 |
Structure_Other |
Unassigned |
12
|
Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Cannot see ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. |
| VERO_N_SEGMENT2_CON |
36.11596, -96.99959 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Cannot see ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. |
| VERO_N_SEGMENT2_CON |
36.11598, -97.00806 |
2026-08-27 |
Structure_Other |
Unassigned |
12
|
Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Ground rod not visible. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT2_CON |
36.11598, -97.00806 |
2026-08-27 |
Restoration_Other |
Unassigned |
12
|
Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Ground rod not visible. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT2_CON |
36.11598, -97.00806 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Ground rod not visible. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT5_CON |
36.13078, -96.37378 |
2026-08-26 |
Restoration_Other |
Unassigned |
12
|
Vault is washing out |
| VERO_N_SEGMENT2_CON |
36.11614, -96.98919 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Take photos from further back to see full restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. |
| VERO_N_SEGMENT5_CON |
36.12849, -96.32774 |
2026-08-26 |
Structure_Other |
Unassigned |
12
|
Smooth terrain around vault. One duct pack not visible. Duct pact must not be crossing, pull ducts back to both sides of the vault for separation, trim to proper length if necessary. Missing ground wire and jumper inside marker post. Missing vero label inside vault. Missing HH label and vero sticker on marker post. |
| VERO_N_SEGMENT2_CON |
36.11636, -96.94323 |
2026-08-27 |
Restoration_Other |
Unassigned |
12
|
Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. |
| VERO_N_SEGMENT2_CON |
36.11636, -96.94323 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. |
| VERO_S_SEGMENT3_CON |
35.98507, -96.72132 |
2026-08-27 |
Restoration_Other |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Sealant missing on conduit. Not all conduit visible |
| VERO_S_SEGMENT3_CON |
35.98507, -96.72132 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Sealant missing on conduit. Not all conduit visible |
| VERO_N_SEGMENT7_CON |
36.13341, -96.05900 |
2026-08-26 |
Structure_Other |
Unassigned |
12
|
Missing all photos. |
| VERO_N_SEGMENT2_CON |
36.11543, -96.82472 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer wire and ground with jumper. Tracer wire must be visible inside vault (not buried). Unable to read HH number on marker post. |
| VERO_N_SEGMENT5_CON |
36.11571, -96.40886 |
2026-08-26 |
Structure_Other |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Apply dirt around vault to bring to grade and restore surrounding softscape. Unbury tracer wire inside vault. Vero sticker not visible on inside vault photo. |
| VERO_N_SEGMENT5_CON |
36.11571, -96.40886 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Apply dirt around vault to bring to grade and restore surrounding softscape. Unbury tracer wire inside vault. Vero sticker not visible on inside vault photo. |
| VERO_N_SEGMENT3_CON |
36.11672, -96.66077 |
2026-08-26 |
Structure_Other |
Unassigned |
12
|
Remove excess rocks behind vault. Missing photo of marker post wiring, hand hole label not legible. Need a closer and clearer photo of the inside vault |
| VERO_N_SEGMENT2_CON |
36.11637, -96.92638 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Take photos from further back to see full restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Ground rod not visible |
| VERO_N_SEGMENT5_CON |
36.11921, -96.40208 |
2026-08-26 |
Pole_Grounding |
Unassigned |
12
|
Marker post needs jumper wire connecting tracer wires to ground. |
| VERO_S_SEGMENT3_CON |
35.98504, -96.69637 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. |
| VERO_N_SEGMENT3_CON |
36.11451, -96.79911 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect jumper between tracer and ground wire in post. Cannot see all of the conduit, obscured by lid. Tracer wire must be visible in vault and not buried |
| VERO_N_SEGMENT2_CON |
36.11633, -96.93485 |
2026-08-27 |
Restoration_Other |
Unassigned |
12
|
Take photos from further back to see full restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT2_CON |
36.11633, -96.93485 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Take photos from further back to see full restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT2_CON |
36.11609, -96.87317 |
2026-08-26 |
Structure_Other |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Unbury conduit from gravel. Backfill dirt around vault to bring to grade. |
| VERO_N_SEGMENT2_CON |
36.11609, -96.87317 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Unbury conduit from gravel. Backfill dirt around vault to bring to grade. Hand Hole label not legible |
| VERO_N_SEGMENT5_CON |
36.12629, -96.38917 |
2026-08-26 |
Structure_Other |
Unassigned |
12
|
Conduit cannot be crossed. Pull back conduit to either side of vault, trim to proper length. Clean dirt from top of vault for pictures. Photo of HH label is too blurry. Jumper wire needs to be connected to tracer and ground. Inside vault picture must show the Vero sticker |
| VERO_N_SEGMENT1_CON |
36.11595, -97.02485 |
2026-08-27 |
Restoration_Other |
Unassigned |
12
|
Take photos from further back to see full restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Ground rod not visible, drain vault. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT1_CON |
36.11595, -97.02485 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Take photos from further back to see full restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Ground rod not visible, drain vault. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT2_CON |
36.11615, -96.88124 |
2026-08-27 |
Restoration_Other |
Unassigned |
12
|
Take photos from further back to show restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Conduit not fully visible. Tracer wire not fully visible. |
| VERO_N_SEGMENT2_CON |
36.11615, -96.88124 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Take photos from further back to show restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Conduit not fully visible. Tracer wire not fully visible. |
| VERO_N_SEGMENT2_CON |
36.11601, -97.01519 |
2026-08-27 |
Restoration_Other |
Unassigned |
12
|
Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Ground rod not visible. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. |
| VERO_N_SEGMENT2_CON |
36.11601, -97.01519 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Ground rod not visible. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. |
| VERO_N_SEGMENT5_CON |
36.13041, -96.38140 |
2026-08-26 |
Pole_Grounding |
Unassigned |
12
|
Conduit cannot be crossed, pull back conduit to both sides of the vault, trim to length afterwards. Connect jumper wire between tracer and ground wire in marker post, remove rocks from surrounding softscape, ground rod must be driven further into the ground. Vero sticker not visible inside vault. |
| VERO_S_SEGMENT3_CON |
35.98579, -96.86603 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Install jumper wire to tracer wire and ground wire in marker post |
| VERO_S_SEGMENT3_CON |
35.98526, -96.70466 |
2026-08-26 |
Restoration_Other |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Unbury tracer wire inside vault. Three-way conduit not visible. Ground rod not visible. Remove rocks from around vault. |
| VERO_S_SEGMENT3_CON |
35.98526, -96.70466 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Unbury tracer wire inside vault. Three-way conduit not visible. Ground rod not visible. Remove rocks from around vault. |
| VERO_S_SEGMENT3_CON |
35.98530, -96.72936 |
2026-08-27 |
Restoration_Other |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_S_SEGMENT3_CON |
35.98530, -96.72936 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT3_CON |
36.11537, -96.81565 |
2026-08-26 |
Restoration_Other |
Unassigned |
12
|
Fill in and compact all sunken softscape around vault and plow lines visible from photos. Drain water and take updated interior vault photo. Connect tracer and ground wire with jumper |
| VERO_S_SEGMENT3_CON |
35.98562, -96.80752 |
2026-08-26 |
Structure_Other |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Unbury tracer wire inside vault. install additional dirt around vault to bring to grade. |
| VERO_S_SEGMENT3_CON |
35.98562, -96.80752 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Unbury tracer wire inside vault. install additional dirt around vault to bring to grade. |
| VERO_N_SEGMENT5_CON |
36.12287, -96.39533 |
2026-08-26 |
Restoration_Other |
Unassigned |
12
|
Inside vault photo must include vero sticker. Install jumper wire between tracer wire and ground inside marker post. |
| VERO_S_SEGMENT3_CON |
35.98518, -96.77406 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
connect tracer and ground wires with jumper in marker post. |
| VERO_N_SEGMENT2_CON |
36.11632, -96.95732 |
2026-08-27 |
Restoration_Other |
Unassigned |
12
|
Take photos from further back to see full restoration. Ground rod not visible. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT2_CON |
36.11632, -96.95732 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Take photos from further back to see full restoration. Ground rod not visible. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT2_CON |
36.11620, -96.97423 |
2026-08-27 |
Structure_Other |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Three-way conduit not visible |
| VERO_N_SEGMENT2_CON |
36.11620, -96.97423 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Three-way conduit not visible |
| VERO_S_SEGMENT3_CON |
35.98579, -96.88243 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer and ground with jumper in marker post. |
| VERO_N_SEGMENT2_CON |
36.11589, -96.85873 |
2026-08-26 |
Restoration_Other |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT2_CON |
36.11589, -96.85873 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT2_CON |
36.11630, -96.96577 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. |
| VERO_S_SEGMENT3_CON |
35.98548, -96.78200 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer and ground with jumper in marker post. |
| VERO_S_SEGMENT3_CON |
35.98554, -96.87404 |
2026-08-26 |
Restoration_Other |
Unassigned |
12
|
Backfill dirt around vault to bring vault to grade. Conduit missing plugs. Connect tracer wire and ground wire with jumper in marker post. |
| VERO_S_SEGMENT3_CON |
35.98554, -96.87404 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Backfill dirt around vault to bring vault to grade. Conduit missing plugs. Connect tracer wire and ground wire with jumper in marker post. |
| VERO_N_SEGMENT2_CON |
36.11652, -96.91083 |
2026-08-27 |
Restoration_Other |
Unassigned |
12
|
Take photos further back to show full restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT2_CON |
36.11652, -96.91083 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Take photos further back to show full restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_S_SEGMENT3_CON |
35.98553, -96.79079 |
2026-08-26 |
Restoration_Other |
Unassigned |
12
|
Backfill softscape around the vault to bring to grade, connect tracer wire and ground wire with jumper in marker post, sealant needed on conduit with fiber. |
| VERO_S_SEGMENT3_CON |
35.98553, -96.79079 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Backfill softscape around the vault to bring to grade, connect tracer wire and ground wire with jumper in marker post, sealant needed on conduit with fiber. |
| VERO_S_SEGMENT3_CON |
35.98568, -96.86806 |
2026-08-26 |
Restoration_Other |
Unassigned |
12
|
backfill dirt around vault to bring vault to grade. Connect tracer and ground wire with jumper in marker post. |
| VERO_S_SEGMENT3_CON |
35.98568, -96.86806 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
backfill dirt around vault to bring vault to grade. Connect tracer and ground wire with jumper in marker post. |
| VERO_S_SEGMENT3_CON |
35.98532, -96.81593 |
2026-08-26 |
Restoration_Other |
Unassigned |
12
|
Missing photo of marker post wiring and label. Apply more dirt around vault to bring to grade, fill in sinking softscape. |
| VERO_S_SEGMENT3_CON |
35.98532, -96.81593 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Missing photo of marker post wiring and label. Apply more dirt around vault to bring to grade, fill in sinking softscape. |
| VERO_S_SEGMENT3_CON |
35.98561, -96.84899 |
2026-08-26 |
Structure_Other |
Unassigned |
12
|
Connect tracer and ground with jumper in marker post. Drain vault and take photo of interior (ensure tracer visibility, ground rod installation, and conduit are sealed) |
| VERO_S_SEGMENT3_CON |
35.98561, -96.84899 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer and ground with jumper in marker post. Drain vault and take photo of interior (ensure tracer visibility, ground rod installation, and conduit are sealed) |
| VERO_S_SEGMENT3_CON |
35.98553, -96.79918 |
2026-08-26 |
Structure_Other |
Unassigned |
12
|
Connect tracer wires and ground wire with a jumper inside marker post. Backfill dirt around vault to bring vault to grade. Conduit around fiber needs sealant. |
| VERO_S_SEGMENT3_CON |
35.98553, -96.79918 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with a jumper inside marker post. Backfill dirt around vault to bring vault to grade. Conduit around fiber needs sealant. |
| VERO_S_SEGMENT3_CON |
35.98560, -96.84083 |
2026-08-26 |
Restoration_Other |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Apply dirt around vault to bring to grade and restore surrounding softscape. Unbury tracer wire inside vault. |
| VERO_S_SEGMENT3_CON |
35.98560, -96.84083 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Apply dirt around vault to bring to grade and restore surrounding softscape. Unbury tracer wire inside vault. |
| VERO_N_SEGMENT2_CON |
36.11558, -96.84156 |
2026-08-26 |
Restoration_Other |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT2_CON |
36.11558, -96.84156 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT2_CON |
36.11620, -96.98326 |
2026-08-27 |
Structure_Other |
Unassigned |
12
|
Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. |
| VERO_N_SEGMENT2_CON |
36.11620, -96.98326 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. |
| VERO_N_SEGMENT2_CON |
36.11550, -96.83337 |
2026-08-26 |
Restoration_Other |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault and restore surrounding softscape and holes. |
| VERO_N_SEGMENT2_CON |
36.11550, -96.83337 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault and restore surrounding softscape and holes. |
| VERO_N_SEGMENT2_CON |
36.11602, -96.86829 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. |
| VERO_N_SEGMENT2_CON |
36.11643, -96.90683 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_S_SEGMENT3_CON |
35.98521, -96.68780 |
2026-08-26 |
Markerpost |
Unassigned |
12
|
Connect tracer wires and ground wire with jumper in marker post. |
| VERO_S_SEGMENT3_CON |
35.98531, -96.67979 |
2026-08-26 |
Restoration_Other |
Unassigned |
12
|
Fill in dirt around vault to bring to grade. |
| VERO_N_SEGMENT2_CON |
36.11642, -96.91792 |
2026-08-27 |
Restoration_Other |
Unassigned |
12
|
Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT2_CON |
36.11642, -96.91792 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT2_CON |
36.11629, -96.94799 |
2026-08-27 |
Structure_Other |
Unassigned |
12
|
Take photos from further back to see full restoration. Vault damaged, vault replacement may be necessary. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT2_CON |
36.11629, -96.94799 |
2026-08-27 |
Restoration_Other |
Unassigned |
12
|
Take photos from further back to see full restoration. Vault damaged, vault replacement may be necessary. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_N_SEGMENT2_CON |
36.11629, -96.94799 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Take photos from further back to see full restoration. Vault damaged, vault replacement may be necessary. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault to bring to grade and restore surrounding softscape. |
| VERO_S_SEGMENT3_CON |
35.98506, -96.65449 |
2026-08-27 |
Conduit_Sealed |
Unassigned |
12
|
Ground rod not visible, conduit not sealed around fiber. |
| VERO_N_SEGMENT3_CON |
36.11132, -96.78441 |
2026-08-27 |
Structure_Other |
Unassigned |
12
|
Need photos post fiber installation. Hand hole label not legible. Conduit not sealed around fiber. Ground wire not connected to ground rod. Remove mule tape from vault lid. |
| VERO_N_SEGMENT3_CON |
36.11132, -96.78441 |
2026-08-27 |
Conduit_Sealed |
Unassigned |
12
|
Need photos post fiber installation. Hand hole label not legible. Conduit not sealed around fiber. Ground wire not connected to ground rod. Remove mule tape from vault lid. |
| VERO_N_SEGMENT3_CON |
36.11132, -96.78441 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Need photos post fiber installation. Hand hole label not legible. Conduit not sealed around fiber. Ground wire not connected to ground rod. Remove mule tape from vault lid. |
| VERO_N_SEGMENT3_CON |
36.10915, -96.77561 |
2026-08-27 |
Structure_Other |
Unassigned |
12
|
Conduit too long. Conduit not sealed. Backfill needed around vault. Hand hole label not legible. |
| VERO_N_SEGMENT3_CON |
36.10915, -96.77561 |
2026-08-27 |
Conduit_Sealed |
Unassigned |
12
|
Conduit too long. Conduit not sealed. Backfill needed around vault. Hand hole label not legible. |
| VERO_N_SEGMENT3_CON |
36.10915, -96.77561 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Conduit too long. Conduit not sealed. Backfill needed around vault. Hand hole label not legible. |
| VERO_S_SEGMENT3_CON |
35.98525, -96.67126 |
2026-08-27 |
Conduit_Sealed |
Unassigned |
12
|
Three-way conduit buried. Backfill and restore softscape around vault. |
| VERO_S_SEGMENT3_CON |
35.98525, -96.67126 |
2026-08-27 |
Restoration_Other |
Unassigned |
12
|
Three-way conduit buried. Backfill and restore softscape around vault. |
| VERO_N_SEGMENT3_CON |
36.10830, -96.76646 |
2026-08-27 |
Conduit_Sealed |
Unassigned |
12
|
Hand hole label not legible. Tracer not visible inside vault. Backfill and restore softscape around vault. |
| VERO_N_SEGMENT3_CON |
36.10830, -96.76646 |
2026-08-27 |
Markerpost |
Unassigned |
12
|
Hand hole label not legible. Tracer not visible inside vault. Backfill and restore softscape around vault. |
| VERO_S_SEGMENT3_CON |
35.98538, -96.63786 |
2026-08-27 |
Structure_Grounding |
Unassigned |
12
|
Remove trash from vault. Backfill and restore softscape around vault. Ground rod not properly installed. |
| VERO_S_SEGMENT3_CON |
35.98540, -96.64617 |
2026-08-27 |
Structure_Grounding |
Unassigned |
12
|
Backfill dirt around vault. Tracer wire inside vault not visible |
| VERO_S_SEGMENT3_CON |
35.98540, -96.64617 |
2026-08-27 |
Restoration_Other |
Unassigned |
12
|
Backfill dirt around vault. Tracer wire inside vault not visible |
| VERO_S_SEGMENT3_CON |
35.98493, -96.66289 |
2026-08-27 |
Trash_Scraps |
Unassigned |
12
|
Remove trash from inside vault. Backfill and restore softscape around vault. |
| VERO_S_SEGMENT3_CON |
35.98528, -97.05100 |
2026-08-25 |
Structure_Grounding |
Unassigned |
13
|
wire or tracer wire inside marker post. |
| VERO_N_SEGMENT3_CON |
36.11451, -96.79910 |
2026-08-24 |
Conduit_Entry |
Unassigned |
14
|
conduit cannot cross, must be on designated sides of the vault |
| VERO_S_SEGMENT3_CON |
36.11553, -97.06261 |
2026-08-20 |
Locate_Other |
Unassigned |
18
|
missing marker post |
| VERO_N_SEGMENT5_CON |
36.12628, -96.38917 |
2026-08-18 |
Conduit_Entry |
Unassigned |
20
|
conduit cannot cross, each package must be on their designated sides |
| VERO_S_SEGMENT3_CON |
36.11553, -97.06258 |
2026-08-17 |
Restoration_Softscape |
Unassigned |
21
|
Vault needs to be re-leveled and surrounding ground sinkage needs to be filled in |
| VERO_N_SEGMENT3_CON |
36.11524, -96.81095 |
2026-07-30 |
Restoration_Softscape |
Unassigned |
39
|
Rocks and trash need to be removed from site |
| VERO_N_SEGMENT3_CON |
36.11492, -96.80304 |
2026-07-30 |
Restoration_Softscape |
Unassigned |
39
|
Rock pile needs to be removed |
| VERO_S_SEGMENT3_CON |
35.99636, -96.60826 |
2026-07-24 |
Restoration_Other |
Unassigned |
45
|
Hydro vac hole needs to be backfilled. |
| VERO_N_SEGMENT2_CON |
36.11533, -96.80992 |
2026-07-23 |
Restoration_Softscape |
Unassigned |
46
|
Rocks need to be removed from job site |
| VERO_N_SEGMENT3_CON |
36.10991, -96.77832 |
2026-07-15 |
Restoration_Other |
Unassigned |
54
|
Rocks per DOT need to be removed so that they can mow grass/ no change as of 08/17 |